toggle report

By default the toggle report command displays to the Main window a list of all nodes that have not transitioned to both 0 and 1 at least once. Also displayed is a summary of the number of nodes checked, the number that toggled, the number that didn't toggle, and a percentage that toggled.

Syntax

toggle report

[-file <filename>] [-summary] [-all]

Arguments

-file <filename>

Specifies a file to which to write the report. If this option is selected, the report is not displayed in the Main window. Optional.

-summary

Selects only the summary portion of the report. Optional.

-all

Lists all nodes checked along with their individual transition to 0 and 1 counts. Optional.

See also

toggle add, toggle reset