In implementing arithmetic circuits be very careful how you write the VHDL code, particularly for designs that are sensitive to area.
For example, consider a clock-enabled counter
process (clock) begin if clock'EVENT and clock='1' then if enable then count <= count + 1; end if; end if; end process
This realises a standard register with incrementer in the feedback loop implementation. But it also creates a multiplexer in the data path to implement the enable logic. Could be quite a bit more area, couldn't it? The use of the if statement for the enable is the source of the problem. How about a solution or two?
One approach is to directly gate the clock,
enabled_clock <= clock and enable; process (enabled_clock) begin if clock'EVENT and clock='1' then count <= count + 1; end if; end process;
which might yield interesting comments at design review time!
However, is that clock gating even necessary?
By re-writing as,
process (clock) begin if clock'EVENT and clock='1' then count <= count + enable; end if; end process;
The carry-in to the incrementer ought to be used by the enable (or perhaps the 1 of the incrementer will be driven by enable). The disadvantage to this approach is that for cases where the enable is on the critical path, the carry-in connection could pose timing problems.
That's all for this month, 'bye for now...